Name: PX high-frequency fatigue testing machine
Manufacturer: Changchun Kexin Testing Machine Co., Ltd.
Purchasing date: October, 2011
Main Specifications:
1. Operating frequency range: 60 ~ 250 Hz
2. Maximum average load: ± 50 kN
3. Maximum one-way pulsating load: ± 50 kN
4. Load fluctuation (8 hours): Average load: ± 0.5% F.S; Alternating Load: ± 0.5% F.S
5. Static Load measurement accuracy: ± 1% of indicated value
6. Operating mode: routine test
7. Timing storage interval: 60 to 7200 seconds
8. Power: AC220V 2 kVA
9. Weight: Host: about 3500 kg
Electric control box: about 100 kg
Common accessories: test fixtures (round bar type specimen fixtures, rectangular specimen fixtures, three-point bending specimen fixtures).
Main application areas: Materials and Metallurgy
Main function: pulling-pulling, pulling-pressure, pressure -pressure, three-point bending fatigue tests.
Person in charge of the equipment: Zhao Wenzhu
Ways of contact: Tel: 83688535; 13709840687
E-mail:
General Operating Procedures
- Power on
- Switch on the control box power, preheat 30 minutes, and then run the program;
- Create new testing records, set experimental parameters, and set up protection;
- Clamp the sample
- Adjust static load;
6. Press the Start button to start the test;
7. After the test ends automatically, unload the sample;
8. Turn off the control box power, and then close the computer.